External cardiac compression may be harmful in some scenarios of pulseless electrical activity.
Name:
Publisher version
View Source
Access full-text PDFOpen Access
View Source
Check access options
Check access options
Authors
Hogan, T SAffiliation
Department of Anaesthesia, UPMC Beacon Hospital, Sandyford, Dublin 18, Ireland. dr.tshogan@eircom.netIssue Date
2012-10MeSH
AnimalsCardiac Output
Cardiopulmonary Resuscitation
Electrophysiological Phenomena
Heart Arrest
Heart Massage
Humans
Models, Cardiovascular
Pulse
Shock, Cardiogenic
Stroke Volume
Vascular Resistance
Vasodilation
Metadata
Show full item recordCitation
External cardiac compression may be harmful in some scenarios of pulseless electrical activity. 2012, 79 (4):445-7 Med. HypothesesJournal
Medical hypothesesDOI
10.1016/j.mehy.2012.06.018PubMed ID
22809840Abstract
Pulseless electrical activity occurs when organised or semi-organised electrical activity of the heart persists but the product of systemic vascular resistance and the increase in systemic arterial flow generated by the ejection of the left venticular stroke volume is not sufficient to produce a clinically detectable pulse. Pulseless electrical activity encompasses a very heterogeneous variety of severe circulatory shock states ranging in severity from pseudo-cardiac arrest to effective cardiac arrest. Outcomes of cardiopulmonary resuscitation for pulseless electrical activity are generally poor. Impairment of cardiac filling is the limiting factor to cardiac output in many scenarios of pulseless electrical activity, including extreme vasodilatory shock states. There is no evidence that external cardiac compression can increase cardiac output when impaired cardiac filling is the limiting factor to cardiac output. If impaired cardiac filling is the limiting factor to cardiac output and the heart is effectively ejecting all the blood returning to it, then external cardiac compression can only increase cardiac output if it increases venous return and cardiac filling. Repeated cardiac compression asynchronous with the patient's cardiac cycle and raised mean intrathoracic pressure due to chest compression can be expected to reduce rather than to increase cardiac filling and therefore to reduce rather than to increase cardiac output in such circumstances. The hypothesis is proposed that the performance of external cardiac compression will have zero or negative effect on cardiac output in pulseless electrical activity when impaired cardiac filling is the limiting factor to cardiac output. External cardiac compression may be both directly and indirectly harmful to significant sub-groups of patients with pulseless electrical activity. We have neither evidence nor theory to provide comfort that external cardiac compression is not harmful in many scenarios of pulseless electrical activity. Investigation using a variety of animal models of pulseless electrical activity produced by different shock-inducing mechanisms is required to provide an evidence base for resuscitation guidelines.Item Type
ArticleLanguage
enISSN
1532-2777ae974a485f413a2113503eed53cd6c53
10.1016/j.mehy.2012.06.018
Scopus Count
Collections
Related articles
- Exercise-induced reduction in systemic vascular resistance: a covert killer and an unrecognised resuscitation challenge?
- Authors: Hogan TS
- Issue date: 2009 Oct
- The influence of nonlinear intra-thoracic vascular behaviour and compression characteristics on cardiac output during CPR.
- Authors: Koeken Y, Aelen P, Noordergraaf GJ, Paulussen I, Woerlee P, Noordergraaf A
- Issue date: 2011 May
- Minimal interruption of cardiopulmonary resuscitation for a single shock as mandated by automated external defibrillations does not compromise outcomes in a porcine model of cardiac arrest and resuscitation.
- Authors: Ristagno G, Tang W, Russell JK, Jorgenson D, Wang H, Sun S, Weil MH
- Issue date: 2008 Nov
- External cardiac compression for pulseless electrical activity in suspected anaphylaxis associated with anaesthesia.
- Authors: Hogan TS
- Issue date: 2011 Apr
- Continuous mechanical chest compression during in-hospital cardiopulmonary resuscitation of patients with pulseless electrical activity.
- Authors: Bonnemeier H, Simonis G, Olivecrona G, Weidtmann B, Götberg M, Weitz G, Gerling I, Strasser R, Frey N
- Issue date: 2011 Feb