• Login
    View Item 
    •   Home
    • Hospital Research
    • Munster
    • Cork University Hospital
    • View Item
    •   Home
    • Hospital Research
    • Munster
    • Cork University Hospital
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Map of Submissions

    Home Page
    UlsterN
    5079
    UlsterS
    5079
    Connacht
    1698
    Munster
    58
    Leinster
    465

    Browse

    All of Lenus, The Irish Health RepositoryCommunitiesTitleAuthorsDate publishedSubjectsThis CollectionTitleAuthorsDate publishedSubjects

    My Account

    LoginRegister

    About

    About LenusDirectory of Open Access JournalsOpen Access Publishing GuideNational Health Library & Knowledge ServiceGuide to Publishers' PoliciesFAQsTerms and ConditionsVision StatementORCID Unique identifiers for ResearchersHSE position statement on Open AccessNational Open Research Forum (NORF)Zenodo (European Open Research repository)

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Fixation of tibial plateau fractures with synthetic bone graft versus natural bone graft: a comparison study.

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Authors
    Ong, J C Y
    Kennedy, M T
    Mitra, A
    Harty, J A
    Affiliation
    Department of Trauma and Orthopaedics, Cork University Hospital, Wilton, Cork, Ireland. josh.cy.ong@gmail.com
    Issue Date
    2012-06
    MeSH
    Adult
    Aged
    Biocompatible Materials
    Bone Transplantation
    Female
    Fracture Fixation, Internal
    Humans
    Hydroxyapatites
    Knee Joint
    Male
    Middle Aged
    Range of Motion, Articular
    Tibial Fractures
    Show allShow less
    
    Metadata
    Show full item record
    Citation
    Fixation of tibial plateau fractures with synthetic bone graft versus natural bone graft: a comparison study. 2012, 181 (2):247-52 Ir J Med Sci
    Journal
    Irish journal of medical science
    URI
    http://hdl.handle.net/10147/250256
    DOI
    10.1007/s11845-011-0797-y
    PubMed ID
    22228265
    Abstract
    The goal of this study was to determine differences in fracture stability and functional outcome between synthetic bone graft and natural bone graft with internal fixation of tibia plateau metaphyseal defects.
    Item Type
    Article
    Language
    en
    ISSN
    1863-4362
    ae974a485f413a2113503eed53cd6c53
    10.1007/s11845-011-0797-y
    Scopus Count
    Collections
    Cork University Hospital

    entitlement

    Related articles

    • Experimental tibial plateau fractures augmented with calcium phosphate cement or autologous bone graft.
    • Authors: Welch RD, Zhang H, Bronson DG
    • Issue date: 2003 Feb
    • Long-term radiographic appearance of calcium-phosphate synthetic bone grafts after surgical treatment of tibial plateau fractures.
    • Authors: Hanke A, Bäumlein M, Lang S, Gueorguiev B, Nerlich M, Perren T, Rillmann P, Ryf C, Miclau T, Loibl M
    • Issue date: 2017 Dec
    • Comparison of autogenous bone graft and endothermic calcium phosphate cement for defect augmentation in tibial plateau fractures. A multicenter, prospective, randomized study.
    • Authors: Russell TA, Leighton RK, Alpha-BSM Tibial Plateau Fracture Study Group
    • Issue date: 2008 Oct
    • Autologous Iliac Bone Graft Compared with Biphasic Hydroxyapatite and Calcium Sulfate Cement for the Treatment of Bone Defects in Tibial Plateau Fractures: A Prospective, Randomized, Open-Label, Multicenter Study.
    • Authors: Hofmann A, Gorbulev S, Guehring T, Schulz AP, Schupfner R, Raschke M, Huber-Wagner S, Rommens PM, CERTiFy Study Group
    • Issue date: 2020 Feb 5
    • Augmentation of tibial plateau fractures with an injectable bone substitute: CERAMENT™. Three year follow-up from a prospective study.
    • Authors: Iundusi R, Gasbarra E, D'Arienzo M, Piccioli A, Tarantino U
    • Issue date: 2015 May 13
    Health Library Ireland | Health Service Executive | Jervis House, Jervis Street | Republic of Ireland | Eircode: D01 W596
    lenus@hse.ie | Tel: +353-1-7786275
    DSpace software copyright © 2002-2017  DuraSpace
    Contact Us | Disclaimer
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.