D'Ancona, Giuseppe
Hargrove, Martin
Hinchion, John
Ramesh, B C
Chughtai, Jehan Zeb
Anjum, Muhammad Nadeem
O'Donnell, Aonghus
Aherne, Tom
Citations
Altmetric:
Advisors
Editors
Other Contributors
Date
2012-02-03T15:08:24Z
Date Submitted
Keywords
Other Subjects
Subject Mesh
Cardiac Pacing, Artificial/*methods
Coronary Artery Bypass/*methods
*Coronary Circulation
Hemodynamics
Humans
Intraoperative Care/*methods
Prospective Studies
*Vascular Patency
Planned Date
Start Date
Collaborators
Principal Investigators
Alternative Titles
Publisher
Abstract
OBJECTIVE: Aim of this study was to investigate modifications of coronary grafts flow during different pacing modalities after CABG. MATERIALS AND METHODS: Two separate prospective studies were conducted in patients undergoing CABG and requiring intraoperative epicardial pacing. In a first study (22 patients) coronary grafts flows were measured during dual chamber pacing (DDD) and during ventricular pacing (VVI). In a second study (10 patients) flows were measured during DDD pacing at different atrio-ventricular (A-V) delay periods. A-V delay was adjusted in 25 ms increments from 25 to 250 ms and flow measurements were performed for each A-V delay increment. A transit time flowmeter was used for the measurements. RESULTS: An average of 3.4 grafts/patient were performed. In the first study, average coronary graft flow was 47.4+/-20.8 ml/min during DDD pacing and 41.8+/-18.2 ml/min during VVI pacing (P = 0.0004). Furthermore average systolic pressure was 94.3+/-10.1 mmHg during DDD pacing and 89.6+/-12.2 mmHg during VVV pacing (P = 0.0007). No significant differences in diastolic pressure were recorded during the two different pacing modalities. In the second study, maximal flows were achieved during DDD pacing with an A-V delay of 175 ms (54+/-9.6 ml/min) and minimal flows were detected at 25 ms A-V delay (38.1+/-4.7 ml/min) (P=ns). No significant differences in systolic or diastolic blood pressure were noticed during the different A-V delays. CONCLUSION: Grafts flowmetry provides an extra tool to direct supportive measures such as cardiac pacing after CABG. DDD mode with A-V delay around 175 ms. should be preferred to allow for maximal myocardial perfusion via the grafts.
Language
eng
ISSN
1010-7940 (Print)
1010-7940 (Linking)
eISSN
ISBN
DOI
10.1016/j.ejcts.2004.03.042
PMID
15200984
PMCID
Sponsorships
Funding Sources
Funding Amounts
Grant Identifiers
Methodology
Duration
Ethical Approval
Embedded videos