Abstract
Nebulization within the tent prevented any increase over background level. Nebulization directly into room air resulted in mean fluorescent particle counts of 4.75 x 105/m3 and 4.21 x 105/m3 for Ventolin and Ipramol, respectively, representing more than 400-fold increases over mean background level. More than 99.3% of drug particles were <2 μm in diameter and therefore small enough to enter the lower respiratory tract.