The OMERACT ultrasound task force--status and perspectives.

Hdl Handle:
http://hdl.handle.net/10147/254761
Title:
The OMERACT ultrasound task force--status and perspectives.
Authors:
Naredo, Esperanza; Wakefield, Richard J; Iagnocco, Annamaria; Terslev, Lene; Filippucci, Emilio; Gandjbakhch, Frederique; Aegerter, Philippe; Aydin, Sibel; Backhaus, Marina; Balint, Peter V; Bruyn, George A W; Collado, Paz; Finzel, Stephanie; Freeston, Jane E; Gutierrez, Marwin; Joshua, Frederick; Jousse-Joulin, Sandrine; Kane, David; Keen, Helen I; Moller, Ingrid; Mandl, Peter; Ohrndorf, Sarah; Pineda, Carlos; Schmidt, Wolfgang A; Szkudlarek, Marcin; Conaghan, Philip G; D'Agostino, Maria-Antonietta
Affiliation:
Hospital Universitario Severo Ochoa, Madrid, Spain. maria-antonietta.dagostino@apr.ap-hop-paris.fr
Citation:
The OMERACT ultrasound task force--status and perspectives. 2011, 38 (9):2063-7 J. Rheumatol.
Publisher:
The Journal of rheumatology
Journal:
The Journal of rheumatology
Issue Date:
Sep-2011
URI:
http://hdl.handle.net/10147/254761
DOI:
10.3899/jrheum.110425
PubMed ID:
21885518
Abstract:
This article reports the most recent work of the Outcome Measures in Rheumatology (OMERACT) Ultrasound Task Force, and highlights the future research priorities discussed at the OMERACT 10 meeting. Results of the following studies were presented: (1) intra- and interobserver reliability of ultrasound detecting and scoring synovitis in different joints of patients with rheumatoid arthritis (RA); (2) systematic review of previous ultrasound scoring systems of synovitis in RA; (3) enthesitis systematic review and Delphi definition exercise in spondyloarthritis enthesitis; (4) enthesitis intra- and interobserver reliability exercise; and (5) Delphi definition exercise in hand osteoarthritis, and reliability exercises. Study conclusions were discussed, and a future research agenda was approved, notably further validation of an OMERACT ultrasound global synovitis score (GLOSS) in RA, emphasizing the importance of testing feasibility, predictive value, and added value over standard clinical variables. Future research areas will include validating scoring systems for enthesitis and osteoarthritis, and testing the metric qualities of ultrasound for evaluating tenosynovitis and structural damage in RA.
Item Type:
Article
Language:
en
MeSH:
Arthritis, Rheumatoid; Delphi Technique; Humans; Observer Variation; Synovitis; Ultrasonography, Doppler
ISSN:
0315-162X

Full metadata record

DC FieldValue Language
dc.contributor.authorNaredo, Esperanzaen_GB
dc.contributor.authorWakefield, Richard Jen_GB
dc.contributor.authorIagnocco, Annamariaen_GB
dc.contributor.authorTerslev, Leneen_GB
dc.contributor.authorFilippucci, Emilioen_GB
dc.contributor.authorGandjbakhch, Frederiqueen_GB
dc.contributor.authorAegerter, Philippeen_GB
dc.contributor.authorAydin, Sibelen_GB
dc.contributor.authorBackhaus, Marinaen_GB
dc.contributor.authorBalint, Peter Ven_GB
dc.contributor.authorBruyn, George A Wen_GB
dc.contributor.authorCollado, Pazen_GB
dc.contributor.authorFinzel, Stephanieen_GB
dc.contributor.authorFreeston, Jane Een_GB
dc.contributor.authorGutierrez, Marwinen_GB
dc.contributor.authorJoshua, Fredericken_GB
dc.contributor.authorJousse-Joulin, Sandrineen_GB
dc.contributor.authorKane, Daviden_GB
dc.contributor.authorKeen, Helen Ien_GB
dc.contributor.authorMoller, Ingriden_GB
dc.contributor.authorMandl, Peteren_GB
dc.contributor.authorOhrndorf, Sarahen_GB
dc.contributor.authorPineda, Carlosen_GB
dc.contributor.authorSchmidt, Wolfgang Aen_GB
dc.contributor.authorSzkudlarek, Marcinen_GB
dc.contributor.authorConaghan, Philip Gen_GB
dc.contributor.authorD'Agostino, Maria-Antoniettaen_GB
dc.date.accessioned2012-12-06T11:16:36Z-
dc.date.available2012-12-06T11:16:36Z-
dc.date.issued2011-09-
dc.identifier.citationThe OMERACT ultrasound task force--status and perspectives. 2011, 38 (9):2063-7 J. Rheumatol.en_GB
dc.identifier.issn0315-162X-
dc.identifier.pmid21885518-
dc.identifier.doi10.3899/jrheum.110425-
dc.identifier.urihttp://hdl.handle.net/10147/254761-
dc.description.abstractThis article reports the most recent work of the Outcome Measures in Rheumatology (OMERACT) Ultrasound Task Force, and highlights the future research priorities discussed at the OMERACT 10 meeting. Results of the following studies were presented: (1) intra- and interobserver reliability of ultrasound detecting and scoring synovitis in different joints of patients with rheumatoid arthritis (RA); (2) systematic review of previous ultrasound scoring systems of synovitis in RA; (3) enthesitis systematic review and Delphi definition exercise in spondyloarthritis enthesitis; (4) enthesitis intra- and interobserver reliability exercise; and (5) Delphi definition exercise in hand osteoarthritis, and reliability exercises. Study conclusions were discussed, and a future research agenda was approved, notably further validation of an OMERACT ultrasound global synovitis score (GLOSS) in RA, emphasizing the importance of testing feasibility, predictive value, and added value over standard clinical variables. Future research areas will include validating scoring systems for enthesitis and osteoarthritis, and testing the metric qualities of ultrasound for evaluating tenosynovitis and structural damage in RA.en_GB
dc.language.isoenen
dc.publisherThe Journal of rheumatologyen_GB
dc.rightsArchived with thanks to The Journal of rheumatologyen_GB
dc.subject.meshArthritis, Rheumatoid-
dc.subject.meshDelphi Technique-
dc.subject.meshHumans-
dc.subject.meshObserver Variation-
dc.subject.meshSynovitis-
dc.subject.meshUltrasonography, Doppler-
dc.titleThe OMERACT ultrasound task force--status and perspectives.en_GB
dc.typeArticleen
dc.contributor.departmentHospital Universitario Severo Ochoa, Madrid, Spain. maria-antonietta.dagostino@apr.ap-hop-paris.fren_GB
dc.identifier.journalThe Journal of rheumatologyen_GB
dc.description.provinceLeinsteren

Related articles on PubMed

All Items in Lenus, The Irish Health Repository are protected by copyright, with all rights reserved, unless otherwise indicated.