Independent tunability of the double-mode-locked cw dye laser.

Hdl Handle:
http://hdl.handle.net/10147/143813
Title:
Independent tunability of the double-mode-locked cw dye laser.
Authors:
Bourkoff, E; Whinnery, J R; Dienes, A
Citation:
Independent tunability of the double-mode-locked cw dye laser. 1979, 4 (6):179-81 Opt Lett
Journal:
Optics letters
Issue Date:
1-Jun-1979
URI:
http://hdl.handle.net/10147/143813
PubMed ID:
19687841
Abstract:
We report a new configuration that enables the double-mode-locked cw dye laser to be independently tunable. In addition, the output coupling at each of the two wavelengths can be independently specified. A series of oscillographs shows some interesting features unique to double mode locking and also shows the effects of varying the two cavity lengths with respect to each other.
Item Type:
Article
Language:
en
Description:
Postoperative wound infections remain a major source of upper limb morbidity. The effectiveness of peri-operative human upper limb preparation was determined using a clear fluid antiseptic and an iodine-based solution over 60 and 90 seconds. Less area was missed using iodine over both times and increasing clear solution preparation time from 60 to 90 seconds improved coverage. Surgical experience had little outcome relevance and a 90-second preparation time with either solution was insufficient, with fingers being the sites most commonly missed.
ISSN:
0146-9592

Full metadata record

DC FieldValue Language
dc.contributor.authorBourkoff, Een
dc.contributor.authorWhinnery, J Ren
dc.contributor.authorDienes, Aen
dc.date.accessioned2011-10-03T14:53:40Z-
dc.date.available2011-10-03T14:53:40Z-
dc.date.issued1979-06-01-
dc.identifier.citationIndependent tunability of the double-mode-locked cw dye laser. 1979, 4 (6):179-81 Opt Letten
dc.identifier.issn0146-9592-
dc.identifier.pmid19687841-
dc.identifier.urihttp://hdl.handle.net/10147/143813-
dc.descriptionPostoperative wound infections remain a major source of upper limb morbidity. The effectiveness of peri-operative human upper limb preparation was determined using a clear fluid antiseptic and an iodine-based solution over 60 and 90 seconds. Less area was missed using iodine over both times and increasing clear solution preparation time from 60 to 90 seconds improved coverage. Surgical experience had little outcome relevance and a 90-second preparation time with either solution was insufficient, with fingers being the sites most commonly missed.en
dc.description.abstractWe report a new configuration that enables the double-mode-locked cw dye laser to be independently tunable. In addition, the output coupling at each of the two wavelengths can be independently specified. A series of oscillographs shows some interesting features unique to double mode locking and also shows the effects of varying the two cavity lengths with respect to each other.-
dc.language.isoenen
dc.titleIndependent tunability of the double-mode-locked cw dye laser.en
dc.typeArticleen
dc.identifier.journalOptics lettersen
dc.description.provinceConnacht-

Related articles on PubMed

All Items in Lenus, The Irish Health Repository are protected by copyright, with all rights reserved, unless otherwise indicated.