Abstract:
Abstract Background Long term survivorship in total knee arthroplasty is significantly dependant on prosthesis alignment. Our aim was determine which alignment guide was more accurate in positioning of the tibial component in total knee arthroplasty. We also aimed to assess whether there was any difference in short term patient outcome. Method A comparison of intramedullary versus extramedullary alignment jig was performed. Radiological alignment of tibial components and patient outcomes of 103 Triathlon total knee arthroplasties were analysed. Results Use of the intramedullary was found to be significantly more accurate in determining coronal alignment (p = 0.02) while use of the extramedullary jig was found to give more accurate results in sagittal alignment (p = 0.04). There was no significant difference in WOMAC or SF-36 at six months. Conclusion Use of an intramedullary jig is preferable for positioning of the tibial component using this knee system.
Item Type:
Journal Article

Full metadata record

DC FieldValue Language
dc.contributor.authorCashman, James P-
dc.contributor.authorCarty, Fiona L-
dc.contributor.authorSynnott, Keith-
dc.contributor.authorKenny, Paddy J-
dc.date.accessioned2011-09-26T10:01:15Z-
dc.date.available2011-09-26T10:01:15Z-
dc.date.issued2011-08-20-
dc.identifierhttp://dx.doi.org/10.1186/1749-799X-6-44-
dc.identifier.citationJournal of Orthopaedic Surgery and Research. 2011 Aug 20;6(1):44-
dc.identifier.urihttp://hdl.handle.net/10147/143192-
dc.description.abstractAbstract Background Long term survivorship in total knee arthroplasty is significantly dependant on prosthesis alignment. Our aim was determine which alignment guide was more accurate in positioning of the tibial component in total knee arthroplasty. We also aimed to assess whether there was any difference in short term patient outcome. Method A comparison of intramedullary versus extramedullary alignment jig was performed. Radiological alignment of tibial components and patient outcomes of 103 Triathlon total knee arthroplasties were analysed. Results Use of the intramedullary was found to be significantly more accurate in determining coronal alignment (p = 0.02) while use of the extramedullary jig was found to give more accurate results in sagittal alignment (p = 0.04). There was no significant difference in WOMAC or SF-36 at six months. Conclusion Use of an intramedullary jig is preferable for positioning of the tibial component using this knee system.-
dc.titleIntramedullary versus extramedullary alignment of the tibial component in the Triathlon knee-
dc.typeJournal Article-
dc.language.rfc3066en-
dc.rights.holderCashman et al.; licensee BioMed Central Ltd.-
dc.description.statusPeer Reviewed-
dc.date.updated2011-09-24T19:08:52Z-
All Items in Lenus, The Irish Health Repository are protected by copyright, with all rights reserved, unless otherwise indicated.