Abstract:
The Oregon Health Science University (OHSU) four-chamber oral wear simulator was used to examine the impact of halogen irradiance on the short- and long-term wear behavior of four-methacrylate resin-based composites (RBCs). The hypothesis proposed was that exacerbated wear would occur following the long-term wear of RBCs irradiated under non-optimized irradiance conditions.; Disc-shaped specimens (12.0+/-0.1mm diameter and 2.0+/-0.1mm height) of each RBC were prepared at irradiances of 650+/-14, 530+/-8, 420+/-14, 350+/-8, 270+/-8, 230+/-14, 190+/-8, and 150+/-8 mW/cm(2), respectively. Short-term three-body wear simulation was carried out for 50,000 cycles and long-term was performed up to 500,000 cycles. The wear facets were analyzed using a non-contact optical profilometer. One-, two-, and three-way analyses of variance (ANOVA) were made at P=0.05, guided as necessary by Tukeys correction in multiple partial analyses of the mean total volumetric wear and mean maximum wear depth.; For the short-term wear resistance, the two-way ANOVA identified no significant difference in the mean total volumetric wear (P=0.188) although the mean total wear depth was identified to be significant (P=0.024). The long-term wear resistance for the mean total volumetric wear identified significant differences for each RBC at varying irradiances with the number of cycles but not for the mean maximum wear depth.; The increased number of ploughing actions of the antagonist on the RBC (long-term) results in increased friction which would be expected to play a major role in the wear process. The significant increase in the mean total volumetric wear, but not the mean maximum wear depth, observed over time which is exacerbated at reduced halogen irradiances emphasizes the arguments of DeLong for the employment of volume for evaluating material loss due to wear following in vitro wear simulation of RBCs.
Item Type:
Article
Language:
en
MeSH:
Bisphenol A-Glycidyl Methacrylate; Composite Resins; Curing Lights, Dental; Dental Materials; Dental Restoration Wear; Humans; Light; Materials Testing; Methacrylates; Polyethylene Glycols; Polymethacrylic Acids; Polyurethanes; Silicon Dioxide; Stress, Mechanical; Surface Properties; Time Factors; Zirconium
ISSN:
1879-0097

Full metadata record

DC FieldValue Language
dc.contributor.authorBhamra, Gurcharn Sen
dc.contributor.authorFleming, Garry J Pen
dc.date.accessioned2011-03-14T12:59:35Z-
dc.date.available2011-03-14T12:59:35Z-
dc.date.issued2009-02-
dc.identifier.citationInfluence of halogen irradiance on short- and long-term wear resistance of resin-based composite materials. 2009, 25 (2):214-20 Dent Materen
dc.identifier.issn1879-0097-
dc.identifier.pmid18674811-
dc.identifier.doi10.1016/j.dental.2008.06.007-
dc.identifier.urihttp://hdl.handle.net/10147/124486-
dc.description.abstractThe Oregon Health Science University (OHSU) four-chamber oral wear simulator was used to examine the impact of halogen irradiance on the short- and long-term wear behavior of four-methacrylate resin-based composites (RBCs). The hypothesis proposed was that exacerbated wear would occur following the long-term wear of RBCs irradiated under non-optimized irradiance conditions.-
dc.description.abstractDisc-shaped specimens (12.0+/-0.1mm diameter and 2.0+/-0.1mm height) of each RBC were prepared at irradiances of 650+/-14, 530+/-8, 420+/-14, 350+/-8, 270+/-8, 230+/-14, 190+/-8, and 150+/-8 mW/cm(2), respectively. Short-term three-body wear simulation was carried out for 50,000 cycles and long-term was performed up to 500,000 cycles. The wear facets were analyzed using a non-contact optical profilometer. One-, two-, and three-way analyses of variance (ANOVA) were made at P=0.05, guided as necessary by Tukeys correction in multiple partial analyses of the mean total volumetric wear and mean maximum wear depth.-
dc.description.abstractFor the short-term wear resistance, the two-way ANOVA identified no significant difference in the mean total volumetric wear (P=0.188) although the mean total wear depth was identified to be significant (P=0.024). The long-term wear resistance for the mean total volumetric wear identified significant differences for each RBC at varying irradiances with the number of cycles but not for the mean maximum wear depth.-
dc.description.abstractThe increased number of ploughing actions of the antagonist on the RBC (long-term) results in increased friction which would be expected to play a major role in the wear process. The significant increase in the mean total volumetric wear, but not the mean maximum wear depth, observed over time which is exacerbated at reduced halogen irradiances emphasizes the arguments of DeLong for the employment of volume for evaluating material loss due to wear following in vitro wear simulation of RBCs.-
dc.language.isoenen
dc.subject.meshBisphenol A-Glycidyl Methacrylate-
dc.subject.meshComposite Resins-
dc.subject.meshCuring Lights, Dental-
dc.subject.meshDental Materials-
dc.subject.meshDental Restoration Wear-
dc.subject.meshHumans-
dc.subject.meshLight-
dc.subject.meshMaterials Testing-
dc.subject.meshMethacrylates-
dc.subject.meshPolyethylene Glycols-
dc.subject.meshPolymethacrylic Acids-
dc.subject.meshPolyurethanes-
dc.subject.meshSilicon Dioxide-
dc.subject.meshStress, Mechanical-
dc.subject.meshSurface Properties-
dc.subject.meshTime Factors-
dc.subject.meshZirconium-
dc.titleInfluence of halogen irradiance on short- and long-term wear resistance of resin-based composite materials.en
dc.typeArticleen
dc.contributor.departmentMaterials Science Unit, Division of Oral Biosciences, Dublin Dental School & Hospital, Trinity College Dublin, Dublin 2, Ireland.en
dc.identifier.journalDental materials : official publication of the Academy of Dental Materialsen
dc.description.provinceLeinster-

Related articles on PubMed

All Items in Lenus, The Irish Health Repository are protected by copyright, with all rights reserved, unless otherwise indicated.